Annual DRO Calibration and FAGOR DRO Fault Diagnoses and Repair
DRO Maintenance and Calibration
EEC Ltd were recently contacted by a longstanding customer in Hampshire, to preform their annual DRO check over and calibration. The DRO maintenance and calibration was successfully carried out on 7 manual Turret Mills.
Fagor DRO Fault Diagnoses and Repair
Whilst EEC were attending the site, issues were diagnoses on 2 Fagor DRO units, which we quickly turned our attention to. The DRO faults were identified as a damaged X axis scale (due to an accident by the operator) and a missing digit on the Fagor 30i display. Both items were replaced during a subsequent visit and re-calibrated.
During our initial visit 6 DRO Acu-Rite and Fagor systems were tested and calibrated as required, ensuring accuracy to within the display resolution.
EEC also fitted a splash and swarf guard to a new Fagor Linear Scale, to protect the customer’s investment.